17
2021
12
Overload Protection Measures for Electric Actuator Motors
The broadest definition of an actuator is a drive device capable of producing linear or rotary motion, which operates using a specific form of energy and responds to a control signal. Actuators utilize hydraulic, pneumatic, electrical, or other forms of energy and convert it into mechanical force via motors, cylinders, or other mechanisms. Their basic types include three primary drive configurations: part-turn, multi-turn, and linear.
Electric actuator Analysis of the Causes of Overload:
1. The setpoint of the torque-limiting device is incorrect; the stopping torque is lower than the set value, resulting in continuous generation of excessive torque and causing the motor to stall.
2. For certain reasons, the torque limit triggered a fault in the mechanism’s circuitry, resulting in excessive torque.
3. The high ambient operating temperature reduces the motor’s thermal capacity.
4. The supply voltage is too low to generate the required torque, causing the motor to stall.
5. The heat accumulation resulting from continuous operation exceeds the motor’s allowable temperature rise.
Under normal operating conditions and within the specified time frame, the motor will not be overloaded.
The main protective measures for electric actuators include the following:
1. A thermal relay is used to protect the motor against stall conditions.
2. Use a thermostat to protect the motor against overload during continuous operation or electric operation.
3. Short-circuit incidents can be effectively prevented by using fuses or overcurrent relays.
The above outlines the causes of motor overload in electric actuators and the corresponding protective measures, as compiled by China Soupai Shi Automation Technology Co., Ltd. If you are unfamiliar with these causes and safeguards, please feel free to call us for more information.