Operating Procedures and Precautions for Electric Valve Actuators


Electric valve actuator The operating method.
1. Preparations before operation.
1.1 Before operating the valve, carefully read the operating instructions.
1.2 Before operation, be sure to confirm the gas flow direction and carefully check the valve open/close indicators.
1.3 Inspect the exterior of the electric valve to determine whether it is damp. If damp, dry it thoroughly; if any other issues are detected, address them promptly to ensure the valve is free of faults.
1.4 For electric actuators that have been out of service for more than three months, prior to startup, the clutch shall be inspected; after confirming that the handle is in the manual position, proceed to check the motor’s insulation, rotation direction, and electrical circuitry.
2. Precautions for operating electric valves.
2.1 Before starting, ensure the clutch lever is in the correct position.
2.2 If the electric valve is controlled from the control room, set the transfer switch to the REMOTE position, and then use the SCADA system to operate the valve’s on/off function.
2.3 If operating manually, set the transfer switch to the LOCAL position and operate the electric valve locally. When the electric valve opens or closes, it will automatically stop; then return the transfer switch to the middle position.
2.4 When operating valves on-site, monitor the valve’s open/close indication and stem movement; the valve opening degree shall comply with the specified requirements.
2.5 During on-site operation, when fully closing the valve, electric actuation shall be stopped before the valve reaches its fully closed position, and manual fine‑adjustment shall be used instead.
2.6 When the stroke and overtorque controllers fully open or close the valve, attention should be paid to stroke control. If the valve fails to stop at its fully open or fully closed position, an immediate manual emergency stop must be initiated.
2.7 During valve opening and closing, if the signal indicator malfunctions, or if the valve emits any abnormal noises, stop the equipment immediately and perform an inspection.
2.8 After the operation is successful, the power supply to the electric valve shall be switched off.
2.9 When operating multiple valves simultaneously, attention shall be paid to the sequence of operations and compliance with process requirements.
2.10 When opening a large-diameter valve equipped with a bypass valve, if there is a significant pressure differential between the two ends, first open the bypass valve to equalize the pressure, then open the main valve; after the main valve is opened, immediately close the bypass valve.
2.11 When launching or receiving pigging balls (or devices), the ball valves in their path must be fully open.
2.12 Operating ball valves, gate valves, globe valves, and butterfly valves: they must be either fully open or fully closed; adjustment is strictly prohibited.
2.13 When operating gate valves, globe valves, and knife‑gate valves, once the valve is fully closed or fully open to the top or bottom dead center, it should be turned an additional 1/2 to 1 full turn.
Maintain the valve’s electric actuator.
1. Electric valves shall be stored in a dry, well-ventilated indoor space, with both ends of the passage sealed.
2. Regularly inspect electric valves stored for extended periods, remove any dirt, and apply anti-rust oil to the machined surfaces.
3. After installation, regular inspections should be conducted, with the following key items to be checked:
(1) Seal face wear.
(2) Wear of the trapezoidal threads on the valve stem and valve stem nut.
(3) Check whether the packing has become obsolete or ineffective; if damaged, replace it promptly.
(4) After maintenance and reassembly, the electric valve shall undergo a sealing performance test.
For electric valves in operation, all valve components must be complete and undamaged. Flange threads and bolts on the mounting brackets are essential; threads must be intact and free from looseness. If any looseness is detected, promptly tighten the locknuts on the handwheel to prevent wear at the connection or loss of the handwheel and nameplate. Should the handwheel be missing, it must not be replaced with an adjustable wrench; a matching handwheel should be provided without delay. The packing gland must neither tilt nor lack proper pre‑tightening clearance. For electric valves installed in environments prone to contamination by rain, snow, dust, sand, or other debris, a protective cover should be fitted over the valve stem. The scale markings on the electric valve must remain intact, accurate, and legible. The lead seals, caps, and pneumatic accessories of the electric valve must be undamaged. Insulating clamps must show no dents or cracks.
Striking electric valves during operation is prohibited. Do not stand on or support heavy loads, especially with non-metallic and cast-iron electric valves.