Methods for Addressing External Leakage in Electric Control Valves


Familiar Electric control valve As everyone knows, external leakage in electric control valves is a common issue. It has long been a thorn in the side of industry development, which is why we place particular emphasis on addressing this problem. Today, we will introduce six methods for resolving external leakage in electric control valves.
1) Adding sealing grease: For valves that have not been lubricated with sealing grease, consider applying additional sealing grease to enhance the stem’s sealing performance.
2) Adding Packing: To enhance the packing’s sealing performance on the valve stem, an additional layer of packing can be installed. Typically, this is done by using a double‑ or multi‑layer mixed packing configuration, simply increasing the number of packing rings. However, increasing the number from three to five rings yields only marginal improvement.
3) Graphite packing replacement method: While tetrafluoroethylene (PTFE) packing is widely used, electric control valves—operating within a temperature range of –20 to +200°C—exhibit significantly degraded sealing performance and accelerated aging when subjected to large temperature fluctuations, resulting in a shortened service life. Flexible graphite packing, by contrast, addresses these drawbacks and offers a longer service life. Consequently, some manufacturers of electric control valves have switched from PTFE to graphite packing, and even newly purchased valves are increasingly being fitted with graphite packing instead of PTFE.
However, seals using graphite packing exhibit significant hysteresis, and some even show stick-slip behavior from the outset; this must be taken into account.
4) Change the flow direction—method 2 for the P‑valve stem end: When ΔP is large and P1 is also high, sealing P1 is clearly more difficult than sealing P2. Therefore, one can adopt the approach of reversing the flow direction, switching to P1 at the valve stem end and P2 at the valve stem end; this method is particularly effective for valves operating under high pressure and large pressure differentials. For example, in bellows‑type valves, it is generally advisable to prioritize sealing P2.
5) Lens‑gasket sealing method: used for sealing the upper and lower covers, valve seats, and the upper and lower valve bodies. If an electric control valve employs flat‑face sealing, its sealing performance is poor under high temperature and high pressure, often resulting in external leakage; in such cases, a lens‑gasket seal can be employed, delivering satisfactory results.
6) Replacing the sealing gasket: Most electric control valves still use asbestos gaskets, which exhibit poor sealing performance and a short service life at high temperatures, leading to external leakage. In such cases, spiral-wound gaskets can be used; moreover, many plants have now adopted O‑rings and similar alternatives.