13

2022

08

How should an electric actuator for a valve be selected?


Electric valve actuator Typically composed of a dedicated motor, a reduction gear mechanism, a stroke‑control mechanism, a torque‑limiting device, an opening‑position indicator, and a manual‑or‑electric switching mechanism, it is an indispensable actuating device for implementing valve sequence control, automatic control, and remote operation. Its motion can be regulated by stroke, torque, or the magnitude of axial thrust. The operating characteristics and utilization rate of a valve electric actuator depend on the valve type, the actuator’s operating specifications, and the valve’s location within the pipeline or equipment.
Basis for Selecting the Appropriate Valve Actuator
01 Operating Torque
Operating torque is the primary parameter for selecting an electric actuator for a valve. The actuator’s output torque should be 1.2 to 1.5 times the valve’s maximum torque.
02 Valve stem diameter
For multi-turn rising stem valves, if the maximum allowable stem diameter of the electric actuator cannot accommodate the stem of the matched valve, the assembly cannot be configured as an electric‑actuated valve. Therefore, the inner diameter of the hollow output shaft of the valve’s electric actuator must exceed the outer diameter of the rising stem. For quarter‑turn valves and for non‑rising stem valves in multi‑turn applications, although stem diameter clearance is not a concern, the stem diameter and keyway dimensions should still be carefully considered during selection to ensure proper operation after assembly.
03 Output Speed
If the valve is opened or closed too quickly, water hammer can easily occur. Therefore, the appropriate opening and closing speed should be selected based on the specific operating conditions.
04 Operating Thrust
There are two main structural configurations for electric valve actuators: one does not incorporate a thrust plate and directly outputs torque, while the other is equipped with a thrust plate that converts the output torque into output thrust via the valve stem nut housed within the thrust plate.
05 Number of rotations of the output shaft
The number of revolutions of the electric actuator’s output shaft is determined by the valve’s nominal diameter, the stem thread pitch, and the number of thread starts. It is calculated using the formula: M = H / (Z × S), where M represents the total number of revolutions required of the actuator, H is the valve opening stroke, S is the stem thread pitch, and Z is the number of thread starts on the stem.